Respiratory protection program guide
How to Review and Update a Written Respiratory Protection Program
The standard sets no fixed annual program review. Here is what it does require you to keep current, what recurs every year, and how to run an evaluation.
What prompts an update
-
A change calls for an update
- A new hazard or contaminant
- A different respirator, filter or cartridge
- A change in the process, material or ventilation
- A new work area, site or project phase
- A new program administrator
- A change in the rules that apply to you
- Findings from an evaluation, a near miss or employee feedback
-
Update the written program
tune As necessary, no fixed interval
When workplace conditions that affect respirator use change, under (c)(1).
-
Evaluate the workplace and the program
tune As necessary, no fixed interval
To make sure the written program is effectively implemented and continues to be effective, under (l)(1).
groups Regularly
Consult the employees required to use respirators and correct the problems they identify, under (l)(2).
autorenew Then the loop starts again when the next change or finding calls for it.
Short answer. There is no fixed interval. 29 CFR 1910.134(c)(1) requires the program to be updated as necessary to reflect changes in workplace conditions that affect respirator use, and (l)(1) requires evaluations of the workplace as necessary to confirm the written program is being carried out and remains effective. OSHA’s 1998 memo says there is no required interval for that evaluation. What does recur every year is fit testing for tight-fitting respirators ((f)(2)) and retraining ((k)(5)). Medical re-evaluation follows the events in (e)(7) and the clinician’s written recommendation, not the calendar. Keep a written copy of the current program ((m)(3)). In QuickCare’s builder, edits in setup are free; you pay $199 once for the first formally issued version and $99 once for a later one, offered only when your configuration changes what the document states.
What the standard requires: update, evaluate, consult
Paragraph references are to 29 CFR 1910.134. California’s section 5144 has the same duties.
Where this page sits in the program
The provision this page is about is (ix), evaluating the program. The duties in the table below come from it and from paragraphs (c)(1), (l) and (m).
-
(i) Selecting respirators Paragraph (d)Respirator selection guide arrow_forward
-
(ii) Medical evaluations Paragraph (e)Medical clearance guide arrow_forward
-
(iii) Fit testing for tight-fitting respirators Paragraph (f)Fit test vs. medical clearance arrow_forward
-
(iv) Proper use, routine and emergency Paragraph (g)
-
(v) Cleaning, storing, inspecting and repairing Paragraph (h)
-
(vi) Breathing air, for supplied-air and SCBA Paragraph (i)
-
(vii) Training in the respiratory hazards Paragraph (k)Respirator training arrow_forward
-
(viii) Training in the proper use of respirators Paragraph (k)Respirator training arrow_forward
-
(ix) Evaluating the program Paragraph (l)check Covered on this page Review and update a program arrow_forward
| Duty | When | What it means | Paragraph |
|---|---|---|---|
| Keep the written program current | As necessary, when workplace conditions that affect respirator use change | OSHA’s memo says the written program should be updated whenever the change occurs. | (c)(1) |
| Have procedures for evaluating effectiveness | Written into the program | The standard says “regularly” but sets no interval, so your procedure states yours. | (c)(1)(ix) |
| Evaluate the workplace | As necessary | To make sure the current written program is effectively implemented and continues to be effective. | (l)(1) |
| Consult employees | Regularly | Ask the employees required to use respirators about fit, selection, use under real conditions and maintenance, and correct the problems they identify. | (l)(2) |
| Have the administrator conduct the evaluations | When evaluations are due | The designated program administrator administers or oversees the program and conducts the required evaluations of its effectiveness. | (c)(3) |
| Retain a written copy of the current program | Always | Written materials that must be retained are available on request to affected employees and to OSHA ((m)(4)). | (m)(3) |
What the standard does not say. Neither 1910.134 nor section 5144 requires an annual review of the written program. OSHA’s 1998 question-and-answer memo says so for paragraph (l)(1): an annual written program review is not required, but a program review and revision is required as necessary based on workplace changes. Some other standards do set review intervals for their own plans, for example the silica exposure control plan, which must be reviewed at least annually (29 CFR 1926.1153(g)(2)). That is a different document from your respiratory protection program.
What recurs every year, and what does not
People often call the annual items a “program review.” They are separate duties with their own paragraphs.
-
event_repeat Every year
Fit testing for tight-fitting respirators, at least annually ((f)(2)).
Retraining, annually ((k)(5)).
-
notification_important When a listed event occurs
Medical re-evaluation, in the situations listed in (e)(7), and when the clinician’s written recommendation calls for follow-up. The text sets no calendar interval.
-
tune As necessary, no fixed interval
Updating the written program ((c)(1)).
Evaluating the workplace and the program ((l)(1)).
| Item | Cadence | Paragraph |
|---|---|---|
| Fit test, tight-fitting respirators | Before initial use, whenever a different facepiece (size, style, model or make) is used, and at least annually. An additional fit test follows a physical change that could affect fit. | (f)(2), (f)(3) |
| Training | Retraining annually, and when changes make earlier training obsolete, when knowledge or use shows inadequacy, or when retraining otherwise appears necessary. | (k)(5) |
| Medical evaluation | Before fit testing or required use. Additional evaluations at least in the situations listed in (e)(7): symptoms reported, a PLHCP, supervisor or administrator says re-evaluation is needed, program information indicates it, or a change in workplace conditions substantially raises the physiological burden. Also whenever the clinician’s written recommendation calls for follow-up. The text sets no calendar interval. | (e)(1), (e)(6), (e)(7) |
| Updating the written program | As necessary. | (c)(1) |
| Evaluating the workplace and the program | As necessary. | (l)(1) |
For the annual items, see the annual respirator fit testing checklist for employers and the medical evaluation guide, which explains the re-evaluation triggers.
Changes that call for an update
Anything that changes workplace conditions affecting respirator use. The provisions to look at are those in 1910.134(c)(1).
| What changed | Provisions to look at |
|---|---|
| A new hazard or contaminant, or a higher exposure estimate | Respirator selection (c)(1)(i), including cartridge change schedules; training in the hazards (c)(1)(vii); whether more employees now need to be in the program. |
| A different respirator type, model, filter or cartridge | Selection (c)(1)(i); fit testing (c)(1)(iii), since a different facepiece needs a new fit test ((f)(2)); cleaning and storage (c)(1)(v); training in proper use (c)(1)(viii). |
| A change in the process, material or ventilation | Selection; proper use (c)(1)(iv); how effectiveness is evaluated (c)(1)(ix). |
| A new work area, site or project phase | The worksite-specific procedures themselves ((c)(1)), including emergency procedures. |
| A new program administrator or changed responsibilities | The administrator designation (c)(3) and every place the program names a responsible person. |
| Findings from an evaluation, a near miss or employee feedback | Whichever provision the finding touches; problems identified through employee consultation must be corrected ((l)(2)). |
| A change in the rules that apply to you | The affected provision, for example the medical evaluation provision (c)(1)(ii) if the proposal described below were finalized. |
Proposed, not final (as of 2026-11-13). In July 2025 OSHA proposed to exempt employees required to wear filtering facepiece respirators or loose-fitting powered air-purifying respirators from the medical evaluation in 29 CFR 1910.134(e) (90 FR 28463). We found no final rule on 2026-11-13, so the current requirement still applies, as do any state-plan rules such as California’s section 5144. Last reviewed 2026-11-13. What the proposal does and does not change.
How to run an evaluation, step by step
- Decide what you are comparing. The written program on paper against what actually happens at the worksite.
- Walk the worksite while respirators are in use. Are the right respirators used for each task? Are seal checks done, and are respirators inspected and stored as the program says?
- Check the records. Fit-test dates, training dates, medical evaluation status, and any inspection and cleaning logs, against the program’s own schedules.
- From (l)(2) Consult the employees who are required to use respirators. Ask about fit, selection, use under real conditions and maintenance ((l)(2)(i) through (iv)). Does it fit through a full shift? Does anything interfere with the work?
- From (l)(2) Correct the problems you find. Problems identified through this assessment must be corrected ((l)(2)). Note who fixed what.
- Update the written program if a finding changes a procedure, and date the revision.
- Record the outcome. The date, who evaluated, what was found and what changed.
autorenew Then the loop starts again when the next change or finding calls for it.
Steps 4 and 5 come straight from (l)(2). The rest is good practice: the standard does not prescribe a form or a checklist.
A worked example
Hypothetical. A metal fabrication shop changes the coating it sprays in one booth, and the new product’s safety data sheet lists a different solvent.
- Selection. Is the cartridge on the current half mask still appropriate for the new vapor? Re-evaluate the exposure and the cartridge change schedule ((c)(1)(i) and paragraph (d)).
- Fit. If the shop moves to a different facepiece, each wearer needs a fit test with it ((f)(2)).
- Medical. If the new respirator or conditions substantially raise the physiological burden, additional evaluations may be needed ((e)(7)(iv)).
- Training. Retrain, because the change makes earlier training obsolete ((k)(5)(i)).
- The program. Update the selection and cleaning or change-schedule procedures, date the revision, and keep the current copy ((m)(3)).
The same steps apply whatever tool holds the program: a Word file, a binder or an online builder.
What to keep
Keep a written copy of the current program ((m)(3)). The other records the standard requires, with the paragraph for each, are listed in the records section of the written program guide. One addition for a program you update:
- Earlier versions. Paragraph (m)(3) does not ask for them, but keeping dated earlier versions helps you show what the program said at a given time. This is good practice, not a requirement.
California’s section 5144(m) is parallel. For the practical side of these records, see what records employers should keep after respirator fit testing.
Changing your program in QuickCare’s builder: free edits and new issued versions
If you keep your program in QuickCare’s online builder, two things are worth keeping apart. Your configuration is the program as you have set it up. A formally issued version is a dated PDF generated from one active configuration, kept exactly as issued.
Program setup, edits in setup, previews, activating a configuration, configuration history and downloads of any issued version cost nothing. You pay only when you have a version formally issued.
Pay $199 once by card when you issue your program; your price is shown before you pay. A later new issued version is $99, also once, and is offered only when your active configuration changes what the document states.
An issued version is never edited. When your active configuration changes anything the document states, even a phone number, you need a new issued version, which is a separate one-time payment. When it changes nothing the document states, you do not need one.
Enterprise agreements may include issuance or set their own price. If your organization has an enterprise agreement with QuickCare, or is discussing one, ask us before you issue it.
An issued version is a snapshot. If your practice changes and the written program you rely on should change with it, make the change in your setup and decide whether to have a new version issued. The standard asks for your program to be updated as conditions change, whatever tool you use.
Activating a configuration records how your program runs. On its own it does not show OSHA compliance: your written program, training, evaluations and records do. QuickCare has not reviewed or certified your program, and a written program is not a determination that your organization complies with OSHA requirements. You remain responsible for its content and for carrying it out.
Questions about reviewing and updating a program
How often must the written respiratory protection program be reviewed?
The standard sets no fixed interval. OSHA's 1998 question-and-answer memo says the same about paragraph (l)(1): an annual written program review is not required, but a program review and revision is required as necessary based on workplace changes. The program must be updated as necessary to reflect changes in workplace conditions that affect respirator use (29 CFR 1910.134(c)(1)), and the employer must evaluate the workplace as necessary to confirm that the written program is being carried out and remains effective ((l)(1)). You may set your own review date as a matter of policy.
Which respiratory protection duties recur every year?
Fit testing for tight-fitting respirators, before first use, when a different facepiece is used and at least annually thereafter (29 CFR 1910.134(f)(2)), and retraining, which is administered annually and when other situations arise ((k)(5)). Medical re-evaluation is not annual by default: paragraph (e)(7) lists the situations that call for additional evaluations, and the clinician's written recommendation can call for follow-up ((e)(6)). The review of the written program itself is as necessary.
What changes mean I should update my program?
Anything that changes workplace conditions affecting respirator use: a new hazard or a different exposure level, a different respirator, filter or cartridge, a change in the process, material or ventilation, a new work area or site, a new program administrator, findings from a program evaluation or employee feedback, and a change in the rules that apply to you. OSHA's 1998 memo gives different respirator choices, changes in fit testing and changed work operations as examples, and says the written program should be updated whenever the change occurs.
How do I evaluate whether my program is effective?
Evaluate the workplace as necessary to confirm that the written program is being carried out and is still effective, and regularly consult the employees who are required to use respirators about respirator fit, selection, use under actual workplace conditions, and maintenance. Any problems you find must be corrected (29 CFR 1910.134(l)(1) and (l)(2)). Writing down what you found and what you changed is good practice and makes the next update easier; the standard does not prescribe a form.
What do I have to keep, and who can ask to see it?
Keep a written copy of the current respirator program (29 CFR 1910.134(m)(3)). Written materials that must be retained are made available on request to affected employees and to OSHA ((m)(4)). Fit-test records are kept until the next fit test ((m)(2)(ii)), and records of medical evaluations are retained and made available under 29 CFR 1910.1020 ((m)(1)). Keeping earlier versions of the program is not in (m)(3), but it helps you show what the program said at a given time. California's section 5144(m) is parallel.
Do I pay each time I change my program in QuickCare's builder?
Program setup, edits in setup, previews, activating a configuration, configuration history and downloads of any issued version cost nothing. You pay only when you have a version formally issued. Pay $199 once by card when you issue your program; your price is shown before you pay. A later new issued version is $99, also once, and is offered only when your active configuration changes what the document states. An issued version is never edited. When your active configuration changes anything the document states, even a phone number, you need a new issued version, which is a separate one-time payment. When it changes nothing the document states, you do not need one.
How we reviewed this page
Last reviewed 2026-11-10. QuickCare Solutions wrote this page from the primary sources listed below and checked each citation against the official text on that date. We re-checked the Federal Register for new documents under RIN 1218-AD48 and the eCFR amendment history of 1910.134 on that date, and compared the update and evaluation paragraphs of 1910.134 with section 5144.
It is general information about the standards, not legal advice, and not a determination that any workplace complies. Standards and agency guidance change. If this page differs from the current official text, the official text controls.
Sources
- 29 CFR 1910.134, Respiratory protection (OSHA) (opens in a new tab)
The federal standard. Paragraph (c) is the written program. - 29 CFR 1910.134 on eCFR (opens in a new tab)
The codified text, with its amendment history. - Questions and Answers on the Respiratory Protection Standard, OSHA memo of August 3, 1998 (opens in a new tab)
Enforcement answers on updating, evaluation intervals, administrators and generic programs. - 29 CFR 1910.1020, Access to employee exposure and medical records (OSHA) (opens in a new tab)
How long medical records are kept, which 1910.134(m)(1) points to. - Title 8 CCR section 5144, Respiratory protection (Cal/OSHA) (opens in a new tab)
California’s standard. Subsection (c) is the written program. - 29 CFR 1926.1153, Respirable crystalline silica in construction (OSHA) (opens in a new tab)
Respirator program, exposure control plan and medical surveillance for silica. - Title 8 CCR section 1532.3, Respirable crystalline silica in construction (Cal/OSHA) (opens in a new tab)
California’s construction silica standard. - Federal Register, 90 FR 28463 (July 1, 2025): proposed amendment of the medical evaluation requirements (opens in a new tab)
OSHA’s proposal. Docket OSHA-2025-0006, RIN 1218-AD48. - Federal Register, 91 FR 33130 (June 3, 2026): notice reopening the rulemaking record (opens in a new tab)
Reopened comments on the 2025 proposal. - Informal public hearing transcript, August 20, 2026 (OSHA) (opens in a new tab)
Hearing on the proposal, including the post-hearing deadlines. - Deregulatory rulemaking (OSHA) (opens in a new tab)
OSHA’s own list of the proposals and their stage.
Respirator guidance
What a written respiratory protection program must contain
The nine provisions in 29 CFR 1910.134(c)(1), with examples.
Read more arrow_forwardRespiratory protection program template: free vs. builder
A fair comparison of OSHA’s sample program and an online builder.
Read more arrow_forwardAnnual respirator fit testing checklist
Fit testing is the item that does recur every year; this checklist covers it.
Read more arrow_forwardRespirator medical evaluation guide
What the standard requires and when re-evaluation is triggered.
Read more arrow_forwardUpdate in one place, issue when you are ready
Set up your program free in your QuickCare account and preview it. You pay only when you have a version formally issued.
"Create your free account" opens account creation. After you verify your email and sign in, you set up your organization, then your program.
Already have an account? Sign in
Before you start. It does not include medical evaluations, fit testing, respirator training, a hazard assessment, exposure monitoring or a professional review of your program. Medical evaluations, fit testing and training are separate services that you order on their own, and the hazards your program describes come from your own evaluation of your workplace.
QuickCare has not reviewed or certified your program, and a written program is not a determination that your organization complies with OSHA requirements. You remain responsible for its content and for carrying it out.
The document summarizes the federal standard, 29 CFR 1910.134. It does not cite California's Title 8 section 5144 or other state-plan standards, so employers in California and other state-plan states should check their program against their state's standard.